Quick answer: F1 on an Ideal Logic boiler means the system water pressure has dropped too low (typically below 0.5 bar). In many homes you can restore pressure safely using the filling loop, as your manual describes. If the pressure keeps dropping, there is likely a leak or a faulty part: call a Gas Safe engineer.
If you smell gas: call the National Gas Emergency Service on 0800 111 999 immediately.
Look at the pressure gauge on the front or underside of the boiler. A healthy sealed system is usually around 1 to 1.5 bar when the heating is cold. Below the minimum, the boiler will stop and show F1.
1. Turn the boiler off and let it cool.
2. Check the filling loop is connected at both ends and follow the manual to open the valves slowly until the gauge reaches about 1 to 1.5 bar.
3. Close the valves fully and disconnect the filling loop if your manual advises to do so.
4. Turn the boiler back on and reset if the manual says so.
Do not overfill. If you are unsure, or cannot find the filling loop, call us.
• A small leak on a radiator, valve or pipe
• A faulty pressure relief valve or expansion vessel
• Recently bled radiators (this can lower pressure)
• Water being lost from the system for another reason
If F1 returns within days, the system is losing water. Keep topping up and the underlying fault will get worse. Book an engineer.
• F1 returns after you top up
• you see water around the boiler or pipes
• the gauge will not hold pressure, or climbs very high
• you are unsure about any step
We repair all boiler brands. Repairs are usually booked for the same or next working day, subject to availability. Diagnostic visit: £98 + VAT (£117.60 inc VAT). Office hours 8am to 5pm, Monday to Friday. Book a boiler repair
About 1 to 1.5 bar when cold.
In most homes yes, if your manual shows a filling loop. Follow it exactly.
There is likely a leak or a faulty expansion vessel or relief valve.
It is a safety shutdown, not an emergency, but repeated drops need an engineer.
Yes, we repair all makes across Edinburgh and the Lothians (EH1 to EH30, EH32 to EH35, EH41 and EH52 to EH54).